What is the Medical Floor-Mounted Digital Radiography System XRY-3200T?
The Wincom Medical Floor-Mounted Digital Radiography System XRY-3200T is a 32 kW fixed-site radiography system for general diagnostic imaging. The generator covers 40–125 kV and 32–400 mA with mAs range 0.32–400 and exposure times from 0.002 to 6.3 seconds, using a 1.0/2.0 mm dual-focus tube rotating at 2800 r/min with 1.0 mm Al/75 kV inherent filtration. The system comprises a height-adjustable vertical mast with console and digital display, a 2100×800×650 mm radiographic table with ≥900 mm longitudinal travel, and a wall-mounted receptor stand with an 18×18 inch bucky offering ≥500 mm cassette movement; LED light source, ISO 9001 certification and 380V±38V three-phase supply complete the installation profile. KRIMS Meditech Solutions Limited supplies this equipment with full siting, installation, radiation-protection works, commissioning, application training and after-sales support by factory-trained engineers.
What is it used for?
General digital radiography — chest, abdominal, skeletal and extremity studies — in hospitals, clinics and diagnostic imaging centres.
Clinical and operational benefits
A 32 kW generator with wide kV/mA range and generous table travel covers routine to demanding radiographic studies on one fixed installation.
Key features
- 32 kW output power
- 40–125 kV range
- 32–400 mA range
- 0.32–400 mAs
- 0.002–6.3 s exposure time
- dual focus 1.0/2.0 mm
- 2800 r/min anode speed
- 1.0 mm Al/75 kV inherent filtration
- LED light source
- 2100×800×650 mm table with ≥900 mm longitudinal movement
- 18×18 inch wall bucky with ≥500 mm cassette movement
- ISO 9001.
Technical considerations
Art No.: XRY-3200T | Output power: 32 kW | Power voltage: 380V ±38V | kV range: 40–125 kV | mA range: 32–400 mA | mAs range: 0.32–400 mAs | Exposure time: 0.002–6.3 s | Focus: 1.0 mm (small) / 2.0 mm (large) | Anode speed: 2800 r/min | Inherent filtration: 1.0 mm Al/75 kV | Light source: LED | Table: 2100×800×650 mm, longitudinal movement ≥900 mm | Bucky: 18×18 inch, cassette movement ≥500 mm | Certificate: ISO 9001 — per Wincom Company Ltd. official product specification
Dimensions: Top table size 2100 × 800 × 650 mm
Power requirements: 380V ±38V
Specifications should be confirmed against official Wincom documentation before purchase decisions. Where a specification is not listed here, KRIMS will confirm it with the manufacturer on request.
Who may need it?
- Clinical departments: Radiology & Nuclear Medicine
- Facility types: Hospitals, Diagnostic Centres
How to evaluate this equipment
When reviewing X-Ray Systems, healthcare facilities should assess clinical fit with existing workflows, compliance with applicable standards, integration with installed systems, serviceability, and the availability of qualified biomedical engineering support in their region.
Purchasing considerations
- Availability: On Request
KRIMS provides end-to-end support including supply, installation, commissioning, calibration, preventive maintenance and operator training. Request a quote for current pricing and delivery schedules for the Medical Floor-Mounted Digital Radiography System XRY-3200T (XRY-3200T).