What is the Pocket Fetal Doppler TEC10A?

The Wincom TEC10A is a pocket-sized handheld fetal heart rate detection device using continuous-wave Doppler technology. The measured FHR value and waveform are shown on a 1.77-inch colour LCD, with fetal heart sound available through the built-in speaker or an external headphone. A high-sensitivity 3.0 MHz probe with magnetic docking detects fetal heart sound from 12 weeks of pregnancy, and the unit auto-shuts down after 60 seconds without signal input. Suitable for hospitals, clinics and antenatal self-checks, enabling early monitoring and care. KRIMS Meditech Solutions Limited supplies this device with application guidance, training and after-sales support.

What is it used for?

Fetal heart rate detection and auscultation in antenatal clinics, obstetric wards, midwifery and community care programmes.

Clinical and operational benefits

Visual digits plus waveform with audible heart sound give immediate, confident fetal wellbeing checks from early pregnancy.

Key features

  • Fetal heart sound playback via built-in speaker and external headphone
  • colour display screen
  • FHR digits and waveform curve display
  • magnetic probe docking
  • low-power design
  • battery level indication
  • auto shutdown after 60 s without signal input
  • high-sensitivity Doppler probe detects fetal heart sound from 12 weeks of pregnancy
  • ISO 9001.

Technical considerations

Art. No.: TEC10A | Display: 1.77-inch (35 mm × 28 mm) colour LCD, FHR digits and waveform curve display | FHR measurement range: 50–240 BPM | Resolution: 1 BPM | Accuracy: ±2 BPM | Probe: 3.0 MHz continuous-wave Doppler, magnetic docking (working frequency 3.0 MHz ±10%) | Ultrasound output: negative peak sound pressure p− < 1 MPa; output beam intensity Iob < 20 mW/cm²; spatial-peak temporal-average derived intensity Ispta < 100 mW/cm²; ultrasonic output power P < 20 mW; effective radiating area of transducer ≤ 208 mm² | Power: DC 3 V (two 1.5 V AA LR6 batteries) | Auto shutdown: 60 s after no signal input | Safety classification: internally powered equipment, type CF applied part | Dimensions: 157 mm × 99 mm × 27 mm | Weight: approx. 207 g (with batteries) | Sound output: built-in speaker and external headphone modes | Fetal heart sound audible for pregnancies beyond 12 weeks | Certificate: ISO 9001 — per Wincom Company Ltd. product literature

Dimensions: 157 mm (L) × 99 mm (W) × 27 mm (H)

Weight: Approx. 207 g (with batteries)

Power requirements: DC 3 V — two 1.5 V AA (LR6) batteries

Operating requirements: Internally powered equipment, type CF applied part; auto shutdown after 60 s without signal input

Specifications should be confirmed against official Wincom documentation before purchase decisions. Where a specification is not listed here, KRIMS will confirm it with the manufacturer on request.

Who may need it?

  • Clinical departments: Gynaecology & Obstetrics
  • Facility types: Hospitals, Clinics, NGOs

How to evaluate this equipment

When reviewing Gynaecology & Obstetrics, healthcare facilities should assess clinical fit with existing workflows, compliance with applicable standards, integration with installed systems, serviceability, and the availability of qualified biomedical engineering support in their region.

Purchasing considerations

  • Availability: On Request

KRIMS provides end-to-end support including supply, installation, commissioning, calibration, preventive maintenance and operator training. Request a quote for current pricing and delivery schedules for the Pocket Fetal Doppler TEC10A (TEC10A).

#Wincom#Gynaecology & Obstetrics#Equipment Guide

This article is part of our equipment guide series. View the full product specification and request a quote.

View Product Page

Need equipment, pricing or a project quotation?

Request a Quote

Precisa de ajuda para escolher a tecnologia de saúde certa?

Nossos especialistas estão prontos para apoiar os seus objetivos de saúde.

KRIMS Meditech Solutions Limited

KRIMS MEDITECH SOLUTIONS LIMITED — Africa's leading Healthcare Technology & Hospital Infrastructure Partner. We plan, design, equip, furnish, install, commission, calibrate, maintain, and support entire hospitals, laboratories, research centres, and universities across Africa.

Indústrias & Serviços

Industries Served

HospitalsTeaching HospitalsUniversitiesResearch InstitutesGovernmentMilitaryNGOsPrivate Healthcare

Services Available

SupplyInstallationTrainingCalibrationMaintenanceTechnical SupportCommissioningConsultancy

Fale Conosco

E-mail
krimsmeditechsolutionsltd@gmail.com
Endereço do Escritório
Gongola Off Life Camp Junction
Airport Road
Abuja, Nigeria
Conversar no WhatsApp

Subscreva a Nossa Newsletter

Receba análises de tecnologia de saúde, guias de aquisição e novidades do setor.

© 2026 KRIMS MEDITECH SOLUTIONS LIMITED. Todos os direitos reservados.

We use privacy-friendly first-party analytics to improve this website. Your email or phone is stored only when you submit it through a KRIMS form. Learn more