Electroencephalogram Machine (EEG) EEG-88

Manufacturer: Wincom · Origin: China
SKU: KES-EEG-WINCOM-EEG88 · Model: EEG-88
Wincom 16-channel EEG with 2 ECG channels, 100 dots/s sampling, 12-bit accuracy, ≥10 MΩ input impedance and paper speeds from 5 to 120 mm/s.
Product Overview
The Wincom Electroencephalogram Machine EEG-88 records 16 channels of EEG plus 2 channels of ECG at a 100 dots/s sampling rate with 12-bit accuracy. Input impedance is at least 10 MΩ, patient leakage current is held below 10 µA, and the amplifier provides a magnification multiple of 10,000 with selectable display (paper) speeds of 5, 10, 15, 30, 60 and 120 mm/s and amplitude settings from 1 to 50 mm/50 µV. The headbox panel maps standard 10-20 electrode positions (Fp1, Fp2, F3, F4, C3, C4, P3, P4, O1, O2, F7, F8, T3, T4, T5, T6 and more) with left/right markers and a RUN status indicator. KRIMS Meditech Solutions Limited supplies this equipment with professional installation, commissioning, application training and after-sales support by factory-trained engineers.
Applications
Routine and diagnostic electroencephalography — epilepsy evaluation, encephalopathy, altered-consciousness work-up and neurodiagnostic screening.
Clinical Benefits
Sixteen EEG channels with simultaneous 2-channel ECG and low patient leakage current support safe, diagnostically useful neurophysiology recording.
Key Features
16 channels EEG + 2 channels ECG; 100 dots/s sampling; 12-bit accuracy; input impedance ≥10 MΩ; patient leak current <10 µA; magnification ×10,000; display speeds 5/10/15/30/60/120 mm/s; amplitude 1–50 mm/50 µV; 10-20 electrode mapping headbox with RUN indicator.
Technical Specifications
Art.No.: EEG-88 | Specification: 16 channels of EEG + 2 channels of ECG | Sampling rate: 100 dots/s | Accuracy: 12 bit | Input impedance: ≥10 MΩ | Patient leak current: <10 µA | Magnification multiple: 10,000 | Display speed (paper speed): 5, 10, 15, 30, 60, 120 mm/s | Amplitude: 1, 1.5, 2, 3, 5, 7.5, 10, 12, 15, 20, 30, 50 mm/50 µV — per Wincom Company Ltd. official product specification
Accessories
Included
Headbox with electrode mapping panel, connection cables and documentation as supplied by manufacturer; electrodes per order configuration.
Optional
EEG electrodes, electrode paste and recording supplies per clinical requirements.
Installation Requirements
Examination room with mains power; headbox set-up, electrode preparation guidance and application training on delivery.
Commercial Information
Frequently Asked Questions
Equipment guide in the Knowledge Centre
Read our guide to the Electroencephalogram Machine (EEG) EEG-88: what it is used for, key features, technical considerations and purchasing guidance.