Knowledge CentreBuying Guides

High Frequency Mobile X-Ray Unit XRY-HF50M (XRY-HF50M) — Equipment Guide

KRIMS Meditech Solutions 11 Sept 2026 2 min read
Wincom XRY-HF50M high frequency mobile X-ray unit with wheeled base and articulating tube head arm

What is the High Frequency Mobile X-Ray Unit XRY-HF50M?

The Wincom High Frequency Mobile X-ray Unit XRY-HF50M is a wheeled mobile radiography unit for bedside and ward imaging. A 2.5 kW high-frequency generator inverting at 50 kHz feeds a compact tube head on a swivelling, articulating arm; tube voltage covers 40–100 kV in 1 kV intervals with tube current graded by kV band — 50 mA at 40–49 kV stepping down to 25 mA at 90–100 kV — and mAs selectable from 1.0 to 160 in 45 steps. The wheeled base with braked casters and foot brake allows one-person positioning between bedsides, and the corrugated cable sheathing protects the tube-head feed during movement. KRIMS Meditech Solutions Limited supplies this equipment with installation, radiation-protection commissioning, application training and after-sales support by factory-trained engineers.

What is it used for?

Mobile radiography — chest, abdominal and extremity studies at bedside, in wards, ICUs, emergency departments and clinic settings.

Clinical and operational benefits

High-frequency output with finely stepped kV/mAs delivers consistent image quality at the bedside without transporting critical patients.

Key features

  • 2.5 kW power input
  • 50 kHz main inverter frequency
  • 40–100 kV tube voltage in 1 kV intervals
  • graded tube current by kV band (50 mA at 40–49 kV to 25 mA at 90–100 kV)
  • 1.0–160 mAs in 45 steps
  • wheeled base with foot brake
  • articulating tube-head arm.

Technical considerations

Art. No.: XRY-HF50M | Power input: 2.5 kW | Main invert frequency: 50 kHz | X-ray tube: 1.5 | Tube voltage: 40–100 kV (interval 1 kV) | Tube current: 40–49 kV 50 mA 1–160 mAs; 50–59 kV 42 mA 1–160 mAs; 60–69 kV 35 mA 1–140 mAs; 70–79 kV 31 mA 1–125 mAs; 80–89 kV 28 mA 1–100 mAs; 90–100 kV 25 mA 1–80 mAs | mAs: 1.0–160 mAs (45 steps) — per Wincom Company Ltd. official product specification

Power requirements: 2.5 kW power input

Specifications should be confirmed against official Wincom documentation before purchase decisions. Where a specification is not listed here, KRIMS will confirm it with the manufacturer on request.

Who may need it?

  • Clinical departments: Radiology & Nuclear Medicine, Emergency & Critical Care
  • Facility types: Hospitals, Clinics

How to evaluate this equipment

When reviewing X-Ray Systems, healthcare facilities should assess clinical fit with existing workflows, compliance with applicable standards, integration with installed systems, serviceability, and the availability of qualified biomedical engineering support in their region.

Purchasing considerations

  • Availability: On Request

KRIMS provides end-to-end support including supply, installation, commissioning, calibration, preventive maintenance and operator training. Request a quote for current pricing and delivery schedules for the High Frequency Mobile X-Ray Unit XRY-HF50M (XRY-HF50M).

#Wincom#X-Ray Systems#Equipment Guide

This article is part of our equipment guide series. View the full product specification and request a quote.

View Product Page

Need equipment, pricing or a project quotation?

Request a Quote

Unahitaji msaada kuchagua teknolojia sahihi ya afya?

Wataalamu wetu wako tayari kusaidia malengo yako ya afya.

KRIMS Meditech Solutions Limited

KRIMS MEDITECH SOLUTIONS LIMITED — Africa's leading Healthcare Technology & Hospital Infrastructure Partner. We plan, design, equip, furnish, install, commission, calibrate, maintain, and support entire hospitals, laboratories, research centres, and universities across Africa.

Viwanda na Huduma

Industries Served

HospitalsTeaching HospitalsUniversitiesResearch InstitutesGovernmentMilitaryNGOsPrivate Healthcare

Services Available

SupplyInstallationTrainingCalibrationMaintenanceTechnical SupportCommissioningConsultancy

Wasiliana Nasi

Barua pepe
krimsmeditechsolutionsltd@gmail.com
Anwani ya Ofisi
Gongola Off Life Camp Junction
Airport Road
Abuja, Nigeria
Zungumza kwenye WhatsApp

Jiandikishe kwa Jarida Letu

Pata maarifa ya teknolojia ya afya, miongozo ya ununuzi na habari za sekta.

© 2026 KRIMS MEDITECH SOLUTIONS LIMITED. Haki zote zimehifadhiwa.

We use privacy-friendly first-party analytics to improve this website. Your email or phone is stored only when you submit it through a KRIMS form. Learn more